Kenmore Elite 700 Series Vacuum Manual

The Kenmore Elite 700 Series is a high-performance upright vacuum cleaner featuring powerful suction, advanced filtration with HEPA media, multiple height adjustments for various floor types, a motorized brush roll with on/off control, edge cleaning capability, large capacity dust cup, easy-empty system, onboard tool storage, and a retractable cord. Below are key sections for safety, features, assembly, operation, maintenance, and troubleshooting.

1. Features at a Glance 2. Assembly & Setup 3. First-Time Use 4. Specifications 5. Controls and Settings 6. Using Attachments 7. Cleaning & Maintenance 8. Filtration System 9. Care & Storage 10. Regulatory Information 11. Troubleshooting

Features at a Glance

Key components: Main vacuum body with motor, Handle with controls, Motorized brush roll, Edge cleaning bristles, Large capacity dust cup, HEPA filter, Onboard tool caddy, Retractable power cord.

FeatureDescription
Powerful Suction MotorProvides deep cleaning on carpets and hard floors
Motorized Brush RollWith on/off switch for delicate rugs and hard floors
HEPA Filtration SystemCaptures 99.97% of dust and allergens
5 Height AdjustmentsFor low pile to high pile carpets and bare floors
Edge CleaningBristles along side for cleaning along baseboards
Large Dust CupEasy-empty, bagless design
Onboard Tool StorageHolds crevice tool, upholstery tool, and dusting brush
Retractable Power Cord25-foot cord with automatic rewind
HeadlightIlluminates cleaning path in dark areas
Washable FiltersPre-motor and post-motor filters are washable

Assembly & Setup

Unpack and inspect all contents. Assemble following these steps.

  1. Attach handle: Insert handle into main body until it clicks securely into place.
  2. Install tools: Place crevice tool, upholstery tool, and dusting brush into onboard caddy.
  3. Check filters: Ensure both pre-motor and HEPA filters are properly seated.
  4. Plug into standard 120V AC outlet.

WARNING! Ensure vacuum is unplugged during assembly. Handle with care to avoid pinching fingers.

First-Time Use

Before first use, perform initial setup and test.

  1. Adjust height: Set cleaning height appropriate for your floor type using dial on front.
  2. Test brush roll: Press brush roll on/off button to ensure proper engagement.
  3. Empty dust cup: Ensure dust cup is empty and filters are clean.
  4. Test suction: Vacuum a small area to verify performance.

CAUTION! Keep hair, loose clothing, and fingers away from brush roll when powered on.

Specifications

Controls and Settings

Main controls located on handle. Front Panel: Power switch, Brush roll on/off, Height adjustment dial, Cord rewind pedal.

Handle Controls: Power trigger (hold to operate), Suction control slider, Headlight button.

Height Adjustment: Turn dial to match floor type (1 for bare floors, 5 for thick carpets). Brush Roll: Engage for carpets; turn off for hard floors and delicate rugs. Suction Control: Adjust suction power for different surfaces. Cord Rewind: Step on pedal to automatically retract cord.

Using Attachments

For above-floor cleaning, use onboard tools.

  1. Turn off vacuum and unplug from outlet.
  2. Remove hose from docking port on back of vacuum.
  3. Connect desired tool to end of hose.
  4. Plug in vacuum, press power trigger to use.
  5. Common uses: Crevice tool for tight spaces; upholstery tool for furniture; dusting brush for shelves.

Tip: Ensure hose is fully inserted into docking port for secure connection.

Cleaning & Maintenance

Regular maintenance ensures optimal performance.

  1. Empty dust cup: Press release button, remove cup, empty contents into trash.
  2. Clean brush roll: Remove debris wrapped around roll; check for obstructions monthly.
  3. Wash filters: Remove pre-motor and HEPA filters; rinse with water every 3 months (air dry completely).
  4. Check hose for clogs: Detach and inspect if suction decreases.
  5. Inspect belt: Replace if worn or cracked (approximately every 6-12 months).

WARNING! Always unplug vacuum before performing any maintenance.

Filtration System

HEPA filtration captures allergens. System includes pre-motor foam filter and post-motor HEPA filter. Both are washable. Replace HEPA filter annually or when damaged.

Care & Storage

Store in dry area. Wrap cord around cord hooks. Empty dust cup after each use. Ensure filters are completely dry before reinstalling after washing.

CAUTION! Do not store with wet filters; avoid extreme temperatures.

Regulatory Information

UL Listed; complies with U.S. safety standards. Copyright © Kenmore; trademarks of Sears Brands, LLC. For support, visit www.kenmore.com or contact 1-800-469-4668. This product is for household use only.

Troubleshooting

SymptomPossible CauseCorrective Action
Loss of suctionFull dust cup/clogged filterEmpty dust cup; clean filters; check hose for clogs.
Brush roll not spinningObstruction/belt issueRemove debris from roll; check and replace belt if worn.
Vacuum won't turn onPower source/overheat protectionCheck outlet; ensure cord is plugged in; wait 30 minutes if motor overheated.
Unusual noiseForeign object in brush roll or hoseTurn off and inspect brush roll and hose for obstructions.
Cord not retractingTangled cord/mechanism jamUnplug and manually rewind cord; clear any tangles.

Reset: Unplug for 30 minutes to reset thermal protector.

Service: 1-800-469-4668; www.kenmore.com

Kenmore Elite 700 Series Vacuum Manual © - All Rights Reserved 2025