Kenmore Elite A120E Air Conditioner Manual

The Kenmore Elite A120E is a high-efficiency window air conditioner designed for cooling medium to large rooms. It features electronic controls, multiple fan speeds, energy-saving modes, a programmable timer, remote control operation, washable air filters, and dehumidification function. Below are key sections for safety, features, installation, setup, operation, maintenance, and troubleshooting.

1. Features at a Glance 2. Installation 3. First-Time Setup 4. Specifications 5. Controls and Settings 6. Operating Modes 7. Maintenance 8. Energy Saving Tips 9. Regulatory Information 10. Troubleshooting

Features at a Glance

Key components: Electronic control panel, Remote Control, Washable air filter, Exhaust vent, Energy Saver mode, Sleep mode, Dehumidify function.

FeatureDescription
Cooling Capacity12,000 BTU (suitable for rooms up to 550 sq. ft.)
Energy Efficiency Ratio (EER)High EER rating for reduced energy consumption
Electronic ControlsDigital display with touch controls
Remote ControlFull-function remote for convenient operation
Fan SpeedsMultiple fan speeds (Low, Medium, High, Auto)
Timer Function24-hour programmable on/off timer
Air FilterWashable mesh filter for easy cleaning
Dehumidify ModeRemoves excess moisture from the air
Sleep ModeGradually adjusts temperature for comfortable sleep
Energy Saver ModeFan cycles with compressor to save energy

Installation

Unpack and inspect contents. Ensure window meets requirements.

  1. Prepare window: Measure window opening; ensure it can support unit weight.
  2. Install mounting brackets: Secure brackets according to instructions.
  3. Place unit in window: Lift unit into position with assistance.
  4. Secure unit: Extend side panels; secure with provided screws.
  5. Seal gaps: Use weather stripping to prevent air leaks.
  6. Plug into dedicated outlet: Use 115V, 15-amp grounded outlet.

WARNING! Unit is heavy; use two people for installation. Ensure proper support to prevent falling.

First-Time Setup

After installation, configure initial settings.

  1. Power on: Plug into outlet; unit will beep and display lights.
  2. Set mode: Press MODE to select Cool, Fan, Dry, or Energy Saver.
  3. Set temperature: Use ▲/▼ buttons to set desired temperature (60°F-86°F).
  4. Set fan speed: Press FAN to select Low, Medium, High, or Auto.
  5. Program timer: Press TIMER to set automatic on/off schedule.
  6. Test operation: Allow unit to run for 15 minutes to ensure proper cooling.

CAUTION! Ensure unit is level for proper drainage and operation.

Specifications

Controls and Settings

Control Panel: POWER, MODE, TEMP ▲/▼, FAN, TIMER, SLEEP, ENERGY SAVER.

Remote: POWER, MODE, TEMP ▲/▼, FAN, TIMER, SLEEP, ENERGY SAVER, LIGHT.

Modes: COOL (temperature setting active), FAN (fan only), DRY (dehumidify), ENERGY SAVER (compressor cycles with fan). Fan Speeds: LOW, MEDIUM, HIGH, AUTO (automatically adjusts based on temperature). Timer: Program on/off times in 30-minute increments. Sleep Mode: Gradually increases temperature over 7 hours for energy savings. Temperature Range: 60°F to 86°F in 1° increments.

Operating Modes

Select appropriate mode for your needs.

  1. Cool Mode: For active cooling. Set desired temperature.
  2. Fan Mode: Circulates air without cooling. Select fan speed.
  3. Dry Mode: Removes humidity. Fan runs at low speed.
  4. Energy Saver Mode: Fan cycles with compressor to save energy.
  5. Sleep Mode: Gradually raises temperature 2°F over first hour, then 1°F each following hour for 7 hours total.

Tip: Use Energy Saver mode when room is occupied for extended periods.

Maintenance

Regular maintenance ensures optimal performance.

  1. Clean air filter: Remove and wash filter every 2 weeks during heavy use.
  2. Clean exterior: Wipe cabinet with damp cloth; do not use harsh chemicals.
  3. Clean condenser coils: Vacuum coils annually before cooling season.
  4. Check drainage: Ensure drain holes are clear for proper condensation removal.
  5. Winter storage: Remove unit from window; clean thoroughly; store in dry place.

WARNING! Unplug unit before performing any maintenance.

Energy Saving Tips

Maximize efficiency and reduce energy costs.

Regulatory Information

UL Listed: Meets safety standards. EPA Compliance: Uses R-410A refrigerant, which is ozone-friendly. Energy Star: May qualify for Energy Star certification (check specific model). Copyright © Kenmore; trademarks of Sears Brands, LLC. For support, visit www.kenmore.com or contact 1-800-469-4668.

Troubleshooting

SymptomPossible CauseCorrective Action
Unit not turning onPower supplyCheck outlet; ensure plug is secure; check circuit breaker.
Poor cooling performanceDirty filter/settingsClean air filter; ensure temperature setting is correct; check for obstructions.
Water leaking insideImproper levelingEnsure unit is tilted slightly outward (1/4" to 1/2").
Loud noise/vibrationLoose parts/installationCheck for loose screws; ensure unit is securely mounted.
Remote not workingBatteries/obstructionsReplace batteries; point remote at unit; remove obstacles.
Unit freezing upLow temperature/filterSet temperature higher; clean air filter; run in Fan mode to thaw.
Error code on displaySystem faultNote code; unplug for 5 minutes; plug back in. If persists, contact service.

Reset: Unplug unit for 5 minutes, then plug back in to reset electronic controls.

Service: 1-800-469-4668; www.kenmore.com