Kenmore Intuition Vacuum Manual

The Kenmore Intuition is a powerful upright vacuum cleaner designed for deep cleaning with advanced filtration, intuitive controls, and versatile attachments. It features a multi-cyclonic system, HEPA filtration, adjustable height settings, motorized brush roll, edge cleaning, and a variety of tools for above-floor cleaning. Below are key sections for safety, features, assembly, operation, maintenance, and troubleshooting.

1. Features at a Glance 2. Assembly & Setup 3. First-Time Use 4. Specifications 5. Controls and Settings 6. Using Attachments 7. Maintenance & Cleaning 8. Filtration System 9. Care & Storage 10. Regulatory Information 11. Troubleshooting

Features at a Glance

Key components: Upright vacuum body, Powerhead with motorized brush, Telescopic wand, Hose, Dust cup with filter system, On-board tool storage.

FeatureDescription
Multi-Cyclonic SystemMaintains strong suction by separating dirt from air
HEPA FiltrationCaptures 99.97% of dust and allergens
Motorized Brush RollDeep cleans carpets; automatically adjusts height
Edge CleaningBrushes on sides clean along baseboards
Adjustable Height5 settings for different carpet types and bare floors
On-Board ToolsCrevice tool, dusting brush, upholstery tool stored on vacuum
Quick-Release WandEasy detachment for above-floor cleaning
Bagless Dust CupLarge capacity with easy-empty mechanism
Power SwitchTurns vacuum on/off
HeadlightIlluminates dark areas under furniture

Assembly & Setup

Unpack and inspect all parts. Assemble before first use.

  1. Attach handle: Insert handle into body until it clicks securely.
  2. Install wand: Insert telescopic wand into hose port on vacuum body.
  3. Attach hose: Connect hose to wand and secure with locking mechanism.
  4. Mount tools: Snap crevice tool, dusting brush, and upholstery tool onto storage clips.
  5. Plug into standard 120V AC outlet.

WARNING! Ensure vacuum is unplugged during assembly. Handle with care to avoid pinching fingers.

First-Time Use

Plug in vacuum; ensure all parts are securely connected.

  1. Adjust height: Set dial on powerhead to match floor type (low for bare floors, high for thick carpets).
  2. Turn on: Press power switch; motorized brush will engage automatically on carpet.
  3. Vacuum floors: Push vacuum forward and back in overlapping strokes.
  4. Use attachments: Detach wand and select appropriate tool for furniture, stairs, or crevices.

CAUTION! Keep vacuum away from water and wet surfaces. Do not vacuum large objects that could clog hose.

Specifications

Controls and Settings

Main controls located on handle and powerhead. Handle: Power switch, cord rewind button. Powerhead: Height adjustment dial, brush roll on/off switch, headlight.

Settings: Height dial (1-5 for low pile to high pile carpets, bare floor setting). Brush roll switch (ON for carpets, OFF for bare floors/hard surfaces). Headlight (automatically turns on when vacuum is powered).

Accessories: Quick-release buttons for wand and hose. Dust cup release button for easy emptying.

Using Attachments

For above-floor cleaning: detach wand and select tool.

  1. Turn off vacuum and unplug from outlet before changing attachments.
  2. Press wand release button to detach from vacuum body.
  3. Select tool: Insert crevice tool for tight spaces, dusting brush for shelves, upholstery tool for furniture.
  4. Reattach wand to vacuum when finished.

Tip: Use the brush roll off setting when using attachments on bare floors or delicate surfaces.

Maintenance & Cleaning

Regular maintenance ensures optimal performance.

  1. Empty dust cup: Press release button, remove cup, empty into trash when full.
  2. Clean filters: Remove pre-motor and HEPA filters monthly; tap gently or rinse (if washable) and dry completely.
  3. Clear brush roll: Turn off vacuum, remove debris wrapped around brush roll with scissors.
  4. Check hose for clogs: Detach and inspect if suction decreases.
  5. Inspect belt: Replace if worn or broken (approximately every 6-12 months).

WARNING! Always unplug vacuum before performing maintenance. Do not use damaged belts or filters.

Filtration System

Two-stage filtration: pre-motor filter and HEPA filter. Pre-motor filter protects motor from large particles. HEPA filter captures microscopic allergens. Both filters should be cleaned monthly and replaced annually or when damaged.

Care & Storage

Store in dry, cool area. Wrap cord around cord hooks. Empty dust cup after each use. Clean filters regularly.

CAUTION! Do not store vacuum with wet filters. Keep away from heat sources and direct sunlight.

Regulatory Information

UL Listed: Complies with UL Standard 1017. ETL Certified: Meets North American safety standards. Copyright © Kenmore; trademarks of Sears Brands, LLC. For support, visit www.kenmore.com or contact 1-800-469-4668.

Troubleshooting

SymptomPossible CauseCorrective Action
Vacuum won't turn onPower outlet/cordCheck outlet; ensure cord is plugged in securely; check circuit breaker.
Loss of suctionFull dust cup/clogged filterEmpty dust cup; clean or replace filters; check hose for clogs.
Brush roll not spinningObstruction/belt issueClear debris from brush roll; check and replace belt if worn.
Vacuum overheatsClogged filters/blockageTurn off and unplug; clean filters; clear any blockages in hose or brush roll.
Unusual noiseForeign object in brush/hoseTurn off immediately; inspect brush roll and hose for obstructions.

Reset: Unplug vacuum for 30 minutes if motor overheats.

Service: 1-800-469-4668; www.kenmore.com