The Sears Kenmore air conditioner line includes a variety of window, portable, and through-the-wall units designed for efficient home cooling. These models feature multiple cooling and fan speeds, energy-saving modes, digital/mechanical controls, remote operation, programmable timers, washable filters, and dehumidification functions. Below are key sections covering safety, features, installation, operation, maintenance, and troubleshooting for Kenmore air conditioners.

1. Features at a Glance 2. Installation Guidelines 3. First-Time Setup 4. Specifications 5. Controls and Settings 6. Remote Control Operation 7. Operating Modes 8. Maintenance & Cleaning 9. Energy Saving Tips 10. Regulatory Information 11. Troubleshooting

Features at a Glance

Key components: Cooling unit with compressor, control panel, remote control, air filter, exhaust hose (portable models), mounting kit (window models).

FeatureDescription
Cooling CapacityMeasured in BTUs; varies by model (5,000 to 25,000 BTU)
Energy Efficiency Ratio (EER)High-efficiency ratings for lower energy consumption
Operating ModesCool, Fan Only, Dry (dehumidify), Energy Saver
Fan SpeedsMultiple speeds (Low, Medium, High, Auto)
Digital ControlsLED display with temperature setting and timer
Remote ControlWireless remote for convenient operation
Programmable Timer24-hour on/off timer for scheduled operation
Washable FilterRemovable and washable air filter
Sleep ModeGradually adjusts temperature for nighttime comfort
Power CordStandard 115V grounded plug

Installation Guidelines

Unpack and inspect all parts. Ensure proper support and sealing for window units.

  1. Window Unit Installation: Install mounting brackets, place unit in window, extend side panels, secure with screws, seal gaps with weather stripping.
  2. Portable Unit Installation: Place near window, attach exhaust hose to window kit, seal window adapter, ensure proper ventilation.
  3. Through-the-Wall Installation: Use existing sleeve or install new sleeve per instructions, secure unit, seal gaps.
  4. Electrical Connection: Plug into dedicated 115V outlet; avoid using extension cords.

WARNING! Unit is heavy; use two people for installation. Ensure secure mounting to prevent falling.

First-Time Setup

After installation, perform initial setup for optimal operation.

  1. Power on unit: Plug into outlet, press POWER button on control panel or remote.
  2. Set mode: Select COOL, FAN, DRY, or ENERGY SAVER mode.
  3. Set temperature: Use TEMP buttons to desired setting (usually 72-78°F for cooling).
  4. Set fan speed: Choose LOW, MEDIUM, HIGH, or AUTO fan speed.
  5. Set timer: Program ON/OFF timer if desired.
  6. Install filter: Ensure air filter is properly installed.

CAUTION! Allow unit to sit upright for 24 hours if transported horizontally before operating.

Specifications

Controls and Settings

Control Panel: POWER, MODE, TEMP UP/DOWN, FAN SPEED, TIMER, SLEEP.

Remote Control: POWER, MODE, TEMP, FAN, TIMER, SLEEP, SWING (if equipped).

Mode Settings: COOL (compressor runs), FAN (fan only), DRY (dehumidification), ENERGY SAVER (compressor cycles, fan runs intermittently). Fan Speeds: LOW (quiet), MEDIUM, HIGH (maximum cooling), AUTO (automatically adjusts). Timer: Program unit to turn ON/OFF at specific times. Sleep Mode: Gradually increases temperature over 7 hours for energy savings. Temperature Range: 62°F to 86°F in 1-degree increments.

Remote Control Operation

Remote requires 2 AAA batteries (not included).

  1. Insert batteries with correct polarity.
  2. Point remote at unit's infrared sensor (within 20 feet).
  3. Press POWER to turn unit on/off.
  4. Use MODE to cycle through operating modes.
  5. Adjust temperature with TEMP buttons.
  6. Change fan speed with FAN button.
  7. Set timer with TIMER button.
  8. Activate sleep mode with SLEEP button.

Tip: Remove batteries if remote not used for extended period.

Operating Modes

Supports multiple modes for different needs.

  1. Cool Mode: For standard air conditioning. Set desired temperature and fan speed.
  2. Fan Mode: Circulates air without cooling. Choose fan speed only.
  3. Dry Mode: Reduces humidity. Unit runs at low fan speed, compressor cycles.
  4. Energy Saver Mode: Compressor cycles, fan runs only when cooling. Saves energy.
  5. Sleep Mode: Gradually increases temperature over 7 hours for comfortable sleep and energy savings.
  6. Auto Mode: Unit automatically selects cooling or fan operation based on room temperature.

WARNING! Do not operate in temperatures below 60°F to prevent coil freezing.

Maintenance & Cleaning

Unplug unit before cleaning. Regular maintenance ensures efficiency and longevity.

  1. Filter Cleaning: Remove filter every 2 weeks, wash with mild detergent and water, dry completely before reinstalling.
  2. Exterior Cleaning: Wipe cabinet with soft, damp cloth. Do not use harsh chemicals.
  3. Condenser Coil Cleaning: Vacuum front grille annually to remove dust.
  4. Winter Storage: For window units, remove from window, clean, cover, and store in dry place.
  5. Drainage: Ensure drainage holes (if equipped) are clear for proper condensation removal.

CAUTION! Never use water to clean interior electrical components.

Energy Saving Tips

Maximize efficiency and reduce energy costs.

Regulatory Information

UL Listed: Meets safety standards. Energy Star: Some models qualify for Energy Star certification. EPA Refrigerant Compliance: Uses R-410A, which is ozone-friendly. Copyright © Sears Brands, LLC. For support, visit www.kenmore.com or contact 1-800-469-4663.

Troubleshooting

SymptomPossible CauseCorrective Action
Unit not coolingDirty filter, settings incorrectClean filter; set to COOL mode; lower temperature setting.
Unit not turning onPower issue, timer setCheck outlet; ensure plug is secure; check timer settings.
Water leaking insideImproper installation, clogged drainEnsure unit tilted slightly outward; clear drainage holes.
Loud noise/vibrationLoose parts, uneven surfaceTighten mounting hardware; place on level surface.
Remote not workingBatteries, obstructionReplace batteries; point directly at sensor; remove obstacles.
Ice on coilsLow temperature, dirty filterTurn off unit to defrost; clean filter; check for blocked airflow.
Poor airflowDirty filter, blocked ventsClean filter; ensure nothing blocking front or rear vents.
Error codes on displaySensor issues, system faultsRefer to manual for specific error code; unplug for 10 minutes then restart.

Reset: Unplug unit for 10 minutes, then plug back in to reset electronic controls.

Service: 1-800-469-4663; www.kenmore.com